About this product 7274-11-10 Circuit Breaker, 5925-01-125-5719. * Manufacturer certifications are shipped with your order FREE of charge
 
													 
													 
													 
													 
													 
											| Part Number or Model | 7274-11-10 | 
| Description | Circuit Breaker | 
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 | 
| Actuator Function | Trip-reset | 
| Actuator Position Designation | At pole one | 
| Arc Quenching Method | Air | 
| Body Length | 0.750 inches nominal | 
| Body Width | 0.562 inches nominal | 
| Bushing Length | 0.250 inches nominal | 
| Case Material | Plastic | 
| Center To Center Distance Between Terminals Parallel To Length | 0.703 inches nominal | 
| Circuit Protection Type | Overcurrent single location | 
| Fragility Factor | Moderately rugged | 
| Frequency In Hertz | 400.0 single location | 
| Inclosure Protection Type For Which Designed | Corrosion resistant and sand resistant | 
| Internal Trip Release Configuration | Series trip single location | 
| Main Contact Tripping Mechanism Type | Trip free | 
| Manual Actuator Type And Quantity | 1 push-pull | 
| Maximum Continuous Load Current Rating Per Pole | 10.0 amperes ac single location and 10.0 amperes dc single location | 
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 800.0 ac single location and 2000.0 dc single location | 
| Mounting Facility Type And Quantity | 1 threaded bushing | 
| Mounting Surface To Terminal End Distance | 1.707 inches nominal | 
| Thread Size | 0.469 inches | 
| Operating Voltage Type And Rating Per Pole In Volts | 120.0 ac single location and 28.0 dc single location | 
| Pole Quantity | 1 | 
| Reset Method | Manual | 
| Special Features | Ampere marked on actuator | 
| Storage Type | General purpose warehouse | 
| Terminal Type And Quantity | 2 tab with screw | 
| Thread Qty Per Inch (tpi) | 32 | 
| Thread Series Designator | Uns | 
| Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location | 
| Trip Release Ambient Tempurature Rating | 25.0 degree celsius nominal single location | 
| Trip Release Characteristic | Time delay single location | 
| Trip Release Method | Thermal single location | 
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 145.0 single location | 
| Unpackaged Unit Weight | 1.500 ounces | 
 
			Circuit Breaker. 35 amp,3 phase,miniature,ambient compensated. Light weight,Trip free design AS58091 qualified . Protective Terminal barriers between each phase.
7274-2-1 Circuit Breaker, 5925-00-815-6621
MS2207312 circuit breaker
Commercial 40 amp thermal Circuit Breaker with manual reset. Ignition protected.& sealed. For the harsh environments of truck, bus, off-road, construction & electric vehicles. Features: 30VDC or 120VAC, Open and closed construction, Automatic and manual