(321) 802-5889
(0)
About this product single phase 10 amp. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | MS3320-10 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Trip Release Method | Thermal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
Thread Size | 0.438 inches |
Trip Delay Time In Seconds Per Rated Continuous Current | 1.50 minimum at 200 pct and 40.000 maximum at 200 pct single location |
Thread Series Designator | Un |
Thread Qty Per Inch (tpi) | 32 |
Terminal Type And Quantity | 2 tab with screw |
Storage Type | General purpose warehouse |
Specification Data | 96906-ms3320 government standard |
Reset Method | Manual |
Pole Quantity | 1 |
Operating Voltage Type And Rating Per Pole In Volts | 120 ac and 28 dc single location |
Mounting Surface To Terminal End Distance | 1.343 inches maximum |
Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 5000 ac and 2500 dc single location |
Maximum Continuous Load Current Rating Per Pole | 10 amperes ac and 10 amperes dc single location |
Manual Actuator Type And Quantity | 1 push-pull |
Main Contact Tripping Mechanism Type | Trip free |
Internal Trip Release Configuration | Series trip single location |
Inclosure Protection Type For Which Designed | Fungus resistant and vibration resistant and shock resistant and salt spray proof and dusttight and corrosion resistant and moisture resistant and explosion proof |
Frequency In Hertz | 400 single location |
Fragility Factor | Moderately rugged |
Circuit Protection Type | Overcurrent single location |
Center To Center Distance Between Terminals Parallel To Length | 0.500 inches nominal |
Case Material | Plastic |
Bushing Length | 0.25 inches |
Body Width | 0.593 inches maximum |
Body Style | Single pole type |
Body Length | 0.781 inches maximum |
Actuator Position Designation | At pole one |
Actuator Function | Trip-reset |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138 single location |
Unpackaged Unit Weight | 0.055 pounds |
Circuit Breaker
MS332075 circuit breaker
Circuit Breaker
Milspec trip free high vibration resistance 5 amp aircraft circuit breaker
Circuit Breaker
MS33204 circuit breaker
Circuit Breaker
MS33203 circuit breaker 2TC2-3
Circuit Breaker
MS332025 circuit breaker
Circuit Breaker
MS33202 circuit breaker
MS33203 circuit breaker 2TC2-3
MS332025 circuit breaker
Milspec trip free high vibration resistance 5 amp aircraft circuit breaker
84400057 circuit breaker
This item has been added to your cart!