About this product 50 amperes dc resistive load, moderately rugged. * Manufacturer certifications are shipped with your order FREE of charge
 
													 
													 
													 
											| Part Number or Model | MS24166-D1 | 
| Description | Relay | 
| Schedule B Class | 8536.41.0065 | 
| ECCN (Export Control Class) | 9A991.d | 
| Unthreaded Mounting Hole Diameter | 0.219 inches nominal single mounting facility | 
| Winding Dc Resistance Rating | 94 ohms nominal single winding | 
| Winding Quantity | 1 | 
| Time Delay | 0.02 seconds maximum fixed operate time | 
| Time Delay | 0.01 seconds maximum fixed release time | 
| Storage Type | General purpose warehouse | 
| Terminal Type And Quantity | 4 threaded stud all functions | 
| Overall Height | 2.625 inches maximum | 
| Overall Length | 2.75 inches maximum | 
| Overall Width | 2.125 inches maximum | 
| Purpose For Which Designed | General | 
| Specification Data | 96906-ms24166 government standard | 
| Operating Voltage Rating And Type At Specificationified Temp | 28 volts dc 25 degree celsius single winding | 
| Nonpile-up Main Contact Arrangement | 1 pole, single throw, normally open, double make, momentary action | 
| Main Contact Load Current Rating At Maximum Rated Voltage | 50.0 amperes dc motor load | 
| Main Contact Load Current Rating At Maximum Rated Voltage | 50.0 amperes dc inductive load | 
| Main Contact Load Current Rating At Maximum Rated Voltage | 25.0 amperes dc lamp load | 
| Main Contact Load Current Rating At Maximum Rated Voltage | 50.0 amperes dc resistive load | 
| Main Contact Maximum Voltage Rating In Volts | 28 dc | 
| Mounting Facility Pattern | In-line single mounting facility | 
| Mounting Facility Type And Quantity | 2 unthreaded hole single mounting facility | 
| Fragility Factor | Moderately rugged | 
| Duty Type | Continuous | 
| Cubic Measure | 15.339 cubic inches | 
| Coil Quantity | 1 | 
| Case Material | Metal | 
| Center To Center Distance Between Mounting Facilities Parallel T | 2.188 inches nominal single mounting facility | 
| Arc Quenching Method | Air | 
 
			Relay
Moderately rugged power relay, 5945-01-311-9927
MS25221-1 Switch Guard, 5930-00-615-9215
Military spec locking toggle Switch. 2 pole bonded seal (ON - NONE - ON). 8856K78 has positive make and break action and solder lug termination.
MS25221-1 Switch Guard
Toggle Switch. Military grade environment proof rugged sealed toggle Switch. 2 pole, 3 position, Screw Terminals, Standard toggle lever, 8501K2 offers DPDT (double pole double throw) circuitry and is an excellent toggle Switch for rugged environments. F
This item has been added to your cart!