(321) 802-5889
(0)
About this product single phase 10 amp. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | MS3320-10 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 |
| Trip Release Characteristic | Time delay single location |
| Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
| Thread Size | 0.438 inches |
| Trip Delay Time In Seconds Per Rated Continuous Current | 1.5 minimum at 200 pct and 40 maximum at 200 pct single location |
| Thread Series Designator | Un |
| Thread Qty Per Inch (tpi) | 32 |
| Terminal Type And Quantity | 2 tab with screw |
| Storage Type | General purpose warehouse |
| Specification Data | 96906-ms3320 government standard |
| Reset Method | Manual |
| Pole Quantity | 1 |
| Operating Voltage Type And Rating Per Pole In Volts | 120 ac and 28 dc single location |
| Mounting Surface To Terminal End Distance | 1.343 inches maximum |
| Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 5000 ac and 2500 dc single location |
| Maximum Continuous Load Current Rating Per Pole | 10 amperes ac and 10 amperes dc single location |
| Manual Actuator Type And Quantity | 1 push-pull |
| Main Contact Tripping Mechanism Type | Trip free |
| Internal Trip Release Configuration | Series trip single location |
| Inclosure Protection Type For Which Designed | Fungus resistant and vibration resistant and shock resistant and salt spray proof and dusttight and corrosion resistant and moisture resistant and explosion proof |
| Fragility Factor | Moderately rugged |
| Frequency In Hertz | 400 single location |
| Circuit Protection Type | Overcurrent single location |
| Center To Center Distance Between Terminals Parallel To Length | 0.5 inches nominal |
| Case Material | Plastic |
| Bushing Length | 0.25 inches |
| Body Width | 0.593 inches maximum |
| Body Style | Single pole type |
| Body Length | 0.781 inches maximum |
| Trip Release Method | Thermal single location |
| Actuator Position Designation | At pole one |
| Actuator Function | Trip-reset |
| Unpackaged Unit Weight | 0.055 pounds |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138 single location |
Circuit Breaker
MS332075 circuit breaker, 5925-00-468-2757
Circuit Breaker
Milspec trip free high vibration resistance 5 amp aircraft circuit breaker, 5925-00-452-1270
Circuit Breaker
MS33204 circuit breaker
Circuit Breaker
MS33203 circuit breaker 2TC2-3
Circuit Breaker
MS332025 circuit breaker
Circuit Breaker
MS3320-20 Circuit Breaker
Milspec trip free high vibration resistance 5 amp aircraft circuit breaker, 5925-00-452-1270
MS332025 circuit breaker
MS3320-1 Circuit Breaker
84400057 circuit breaker