About this product Hydraulic magnetic Circuit Breaker, single pole, mounted with 3/8"" threaded bushing, DC, 50/60Hz, 400Hz long time delay 135% trip, 10 amps. The AP, UP fully sealed, magnetic Circuit Breaker combines power Switching and accurate, reliable circuit protection with inverse time delays and trip free features.For more info on creating MIL specific part numbers, please visit : MIL-PRF-39019 on hyperlink below. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | 5925-01-582-0199 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) |
Circuit Breaker
Hydraulic magnetic Circuit Breaker, triple pole with stud Terminals, 50/60Hz motor start/ extra long delay, 40 amps, APL style ""fat"" Handle with 1/4-20 studs, with black Handle marked ON-OFF & I-O, VDE and CCC approved. Airpax type IAL/IUL/IEL/LEL Circ
Circuit Breaker
Three pole Panel seal Circuit Breaker rated at 100 amps 240VAC, 50/60 hertz. It has a time delay curve of 61. IULNK112-37035-4 has a 24 VDC voltage trip coil I pole three.
Circuit Breaker
30 amp Circuit Breaker Airpax type IAL/IUL/IEL/LEL Circuit Breakers are available in a wide variety of configurations, including series, series with auxiliary Switch, shunt and Relay with choice of delays and ratings in DC and/or 50/60Hz or 400 Hz version
Circuit Breaker
Rocker magnetic Circuit Breaker, integral mounting with accidental-off protection, Single pole, DC motor start 125% trip, 10 amps, 1/4-20 (M6) stud Terminals, black rocker with white indicator, vertical mount marked ON/OFF & I/O, 10A, VDE approved.
Circuit Breaker
Circuit Breaker, Type 3 phase, push-pull, trip free, 35 amps. FAA approved part number 10-60806-1035
Circuit Breaker
Hydraulic magnetic Circuit Breaker, three pole with bushing plus (2) 6-32 threaded inserts, screw Terminals, 400Hz short time delay, 15.000 amps. The AP, UP fully sealed, magnetic Circuit Breaker combines power Switching and accurate, reliable circuit p
Fully sealed magnetic Circuit Breaker with auxiliary contacts, low power, trip free, one pole, rated 6.0 amps, standard delay, 50V DC and 240V AC @ 60 Hz and 400Hz. QPL to MIL-PRF-39019. 5 pc minimum
Hydraulic magnetic Circuit Breaker with auxiliary Switch with pierced pin Terminals, single pole, mounted with 3/8"" threaded bushing, DC, 50/60Hz, 400Hz long time delay 135% trip, 5 amps. The AP, UP fully sealed, magnetic Circuit Breaker combines power
Fully sealed magnetic Circuit Breaker, low power, trip free, one pole, screw Terminals, rated 20.0 amps, standard delay, 50V DC and 240V AC @ 60 Hz and 400Hz. QPL to MIL-PRF-39019.
Circuit Breaker. Hydraulic magnetic Circuit Breaker, QPL to MIL-PRF-55629, triple pole, rated xx amps @ (either 50VDC, 240VAC, 50/60Hz or 400Hz). See attached link for exact amperage rating.